01HP is cooling, not electricity
A “1 HP” label describes cooling capacity. The LG 1 HP inverter on this page delivers 2.7 kW of cooling for 770 W of rated input, and averages well below that once the room is cool.
Solar for air-conditioned homes · Cebu
Yes, for the hours the sun is up. A 1 HP inverter aircon running 8 daytime hours uses about 4.0–4.8 kWh, which about 2 panels of 620 W cover on an average Cebu day. A 1.5 HP needs 2–3 panels and a 2 HP unit about 4. At ₱14.89/kWh (VECO, Sep 2026), that 1 HP unit costs ₱1,787–₱2,144 a month to run 8 hours a day.
Night is different. Panels make nothing after dark, so night use is covered by batteries (plan on two for an aircon) or offset by net-metering credits worth about 55–65% of your rate. All figures here are planning estimates.
First, which “solar aircon”?
Search for solar aircon and you’ll find appliances for sale. This guide is about something else: running the aircons in your home on a rooftop system.
The quick answer, by horsepower
Planning figures for 8 hours of daytime use on an average Cebu day, priced at ₱14.89/kWh (VECO, Sep 2026). Your nameplate, room and habits move them.
| Aircon | 620 W panels | Solar for 8 daytime hours | 8 h a day, per month | Cost a month (VECO ₱14.89) | Daytime use per hour (mild–hot afternoon) | Rated input |
|---|---|---|---|---|---|---|
| 1 HP inverter splitVariable speed | 2 | 1.1–1.3 kWp | 120–144 kWh | ₱1,787–₱2,144 | 0.50–0.60 kWh | 770 W |
| 1.5 HP inverter splitVariable speed | 2–3 | 1.4–1.7 kWp | 156–192 kWh | ₱2,323–₱2,859 | 0.65–0.80 kWh | 1,030 W |
| 2 HP inverter splitVariable speed | 4 | 2.2–2.6 kWp | 246–288 kWh | ₱3,663–₱4,288 | 1.02–1.20 kWh | 1,715 W |
| 2.5 HP inverter splitVariable speed · scaled estimate | 4–5 | 2.6–3.0 kWp | 288–336 kWh | ₱4,288–₱5,003 | 1.20–1.40 kWh | 1,850 W |
| 1 HP window typeFixed speed (non-inverter) · listing extract | 3 | 1.7–1.9 kWp | 192–216 kWh | ₱2,859–₱3,216 | 0.80–0.90 kWh | 880 W |
| 1.5 HP window typeFixed speed (non-inverter) · listing extract | 4 | 2.2–2.5 kWp | 246–276 kWh | ₱3,663–₱4,110 | 1.02–1.15 kWh | 1,120 W |
Got more than one aircon, or use them at night? Add each unit and its hours to see your own kWh, panels, batteries and price.
Size solar for my airconsThe aircon estimator
Add each unit, when it runs and whether it must stay on in a brownout. Everything updates as you go and stays on your screen until you ask for a quote.
Aircon solar estimator
Average Cebu day · VECO rate, Sep 2026Sep 2026 household rate per kWh, as published.
Rotations usually last about an hour per area; 2026 red-alert windows ran 3–9 hours, mostly late afternoon and evening.
Aircon electricity, per month
₱4,512/month
303 kWh a month (10.1 kWh a day) at VECO ₱14.89/kWh (Sep 2026).
₱4,512 a month for 303 kWh of aircon use. 2 panels for daytime use. 2 batteries for 4 hours of night backup.
Shows how much of it is aircon, and lets the calculator size your whole home from it.
2 panels · 1.24 kWp
Makes the equivalent of about 96% of your 4.8 kWh of daytime aircon use on an average day. About 70% of that use runs straight from the panels as it happens; the surplus is exported for credit once net metering is approved.
Saves about ₱1,805 a month (estimate; about ₱3,189 with the 4-panel system priced below)
2 batteries · 10.2 kWh
Runs 1 aircon plus essentials for about 7.4 hours (you planned for 4). One battery alone: about 3.7 hours.
Backup load up to 1.4 kW · 5 kW Deye inverter · 2 × about 2.6 kW of battery power (typical 50 A module)
If you sized solar for these aircons alone
Installed list prices from our itemised quote (±8%), before any promotion. Our itemised pricing starts at 4 panels. With 4, the aircon saving rises to about ₱3,189 a month (estimate), and the rest covers other daytime loads. Your final price follows a site assessment.
Estimates for an average day (1,350 kWh per kWp a year), not measured use. Inverter units: 0.4–0.6 kWh per hour for 1 HP up to 0.85–1.2 for 2 HP; night use at the middle of the range, hot afternoons at the top. Essentials on backup: about 0.5 kW. Batteries: 3.69 kWh delivered per 5.12 kWh battery. Exports credited at 55% of your rate, once net metering is approved. Start-up surge isn’t modelled.
The calculator sizes batteries from your whole home’s evening use and may show fewer. With an aircon on the backup circuit we still recommend 2 batteries, and that travels with your quote request.
Want the whole house, not just the aircons? The solar savings calculator starts from your bill.Prices explained line by line: solar installation cost in Cebu.
Day versus night
Cebu’s heat and Cebu’s sunshine peak together, which is why a daytime aircon is the easiest load in the house to put on solar. A home office, a living room in the afternoon or a store open in daylight can run mostly on what the roof makes at that moment.
Bedroom aircons are the opposite: they run from late evening to dawn, when panels make nothing. That use is covered by a battery, by credits earned in the day, or by the grid. How each works is a choice between on-grid, hybrid and off-grid systems.
An aircon day in four chapters
01 / 04Chapter 01
7–11 a.m.
Bedroom aircons switch off around dawn and the panels start slowly. Until the house warms up, most morning output goes to the fridge, fans and pump. Once net metering is approved, any surplus is exported for credit at your utility’s generation charge.
With net metering, exports bank credits for the evening bill
Chapter 02
12–4 p.m.
This is when an inverter aircon works hardest, at the top of its range, and when the panels make the most. Each kWh used as it is made saves the full ₱14.89/kWh (VECO, Sep 2026), worth about 1.5–1.8 times an exported kWh, which earns only the generation charge.
Daytime aircon use is the best use of solar
Chapter 03
6–10 p.m.
After sunset the aircons draw from the grid at the full rate. Credits banked during the day reduce that bill, but each credit is worth only about 55–65% of a kWh you buy. Without a battery, this is the part solar doesn’t cut directly.
Night use is offset at the credit value, not cancelled
Chapter 04
A night rotation
When the grid fails, a grid-tied inverter must shut down. With a hybrid inverter and batteries, the circuits wired to its backup port keep running; everything else goes dark. One 1 HP bedroom unit plus essentials runs about 3½–4½ hours per battery.
Two batteries recommended for any aircon on backup
At your pace. Select any chapter.
Inverter vs conventional
The same 1 HP of cooling, run for the same 8 hours a night. A window unit’s fixed-speed compressor runs flat out, then stops; an inverter slows down once the room is cool.
| 1 HP inverter split | 1 HP window, non-inverter | |
|---|---|---|
| Rated power input | 770 W (LG HS09ISY2) | 880 W (Carrier WCARJ010EE listing extract) |
| DOE label basis | 0.39 kWh per hour (rated × 0.5) | 0.70 kWh per hour (rated × 0.8) |
| Planning average, Cebu night | 0.4–0.6 kWh per hour | 0.7–0.9 kWh per hour |
| 8 hours a night, per month | 120 kWh · ₱1,787 | 192 kWh · ₱2,859 |
| Panels for 8 daytime hours | 2 panels | 3 panels |
| One battery, with essentials | about 3.7 hours | about 2.8 hours |
| Start-up | Soft start: ramps up gently (typical of inverter units) | Each compressor start draws a brief surge well above running power |
Over a month of nights, the window unit in this example uses about 72 kWh more, roughly ₱1,072 at VECO’s Sep 2026 rate. On solar it also needs more panels by day and more battery at night, and its start-up surge is harder on a backup system.
The DOE label’s own method shows the gap: it assumes 9 hours a day and multiplies the rated input by 0.5 for inverter units and 0.8 for fixed-speed ones. An inverter at part load draws far less than its nameplate. In one LBNL worked example, half the cooling took only 40% of the power.
Mixed aircons at home? Get a whole-home estimate in pesos from your own bill. The aircons in the estimator go to the calculator with you, so set yours there first.
Get my whole-home estimateLimits of a horsepower estimate
Two 1.5 HP aircons in the same street can use very different amounts of electricity. These six things explain most of the gap.
A “1 HP” label describes cooling capacity. The LG 1 HP inverter on this page delivers 2.7 kW of cooling for 770 W of rated input, and averages well below that once the room is cool.
The DOE energy label shows a CSPF: cooling delivered per kWh used over a season. Higher is better. The 2021 minimum is 3.08 for units under 3.33 kW of cooling and 2.81 for larger ones; the LG HSN/U18ISA 2 HP lists 5.25. Spec sheets also give an EER, the same ratio at full load (3.50 for the LG 1 HP).
Under the standard used for Philippine labels, a unit at 35 °C outside draws about 9% more power than at 29 °C, and cools about 7% less. Cebu averages 27.1 °C, nearer 28–29 °C in April and May.
ISO 16358 defaults via LBNL (2021); NASA POWER 2001–2025.Each degree cooler costs several percent more energy; the estimator uses about 5% per degree, an estimate. Midea Philippines recommends about 25 °C (Aug 2026).
A 1 HP unit cooling a room that needs 1.5 HP runs at full power for hours; one matched to the room’s floor area and ceiling height idles sooner. A west-facing room, a top floor under a bare metal roof, single glazing or gaps under the door also keep a compressor working harder for longer.
Hours drive the bill. In a survey of 386 Filipino consumers for a 2023 CLASP/DOE study, mostly middle- and high-income aircon owners, 61% ran their aircon more than 6 hours a day, and 62% often or always limited use because of cost.
CLASP / DOE label study, Jan 2023. Not a national household statistic.Batteries for night aircon
A battery’s energy decides how long; its power decides whether the aircon starts at all. Both point to two batteries whenever an aircon is on the backup circuit.
3.69 kWhDelivered per 5.12 kWh battery80% usable × 90% conversion; an estimate until your battery model is confirmed
≈ 7 hEssentials only, per batteryFridge, fan, lights, Wi-Fi and TV at about 0.5 kW
3½–4½ hWith a 1 HP inverter airconPlus essentials, about 0.8–1.0 kW, per battery
≈ 2.6 kWContinuous power, typical 50 A moduleAt 51.2 V; little start-up headroom for one aircon. Your battery’s rating is confirmed in your proposal
Grid-tied inverters must shut down when the grid fails. The hybrid keeps the circuits on its backup port running, so we wire the bedroom you choose to it, not the whole house.
Deye hybrids can deliver twice their rated output for 10 seconds to start motors, but after dark the batteries set the limit: a typical 50 A battery module supplies about 2.6 kW. A second battery gives an aircon room to start alongside the fridge.
Deye’s manual says aircons need at least 2–3 minutes to restart after power returns. A unit with a built-in delay, or a separate backup circuit, helps avoid overload trips.
If the grid fails at midday, the hybrid inverter keeps the backup circuit running from the panels and tops up the battery at the same time.
The Visayas grid logged 93 yellow and 30 red alerts between 1 January and 3 September 2026 (NGCP, via Daily Tribune). Red-alert windows ran 3–9 hours, mostly late afternoon and evening, such as 3–8 p.m. on 11 August, exactly when aircons are on and solar output is fading. Rotations themselves were about an hour per area.
At a Cebu energy summit in October, SunStar reported that shortages are likely to continue through 2027; Energy Secretary Garin said the fix “will be a 2028”. For the full picture, read our guide to battery backup for Cebu brownouts, or compare a solar battery with a generator.
Illustrative scenarios
Worked through the estimator above at ₱14.89/kWh (VECO, Sep 2026), with a 4-hour night brownout. Illustrations of the method, not real installations or quotes.
Scenario A · nights only
Day 0%Night 100%
No daytime use, so panels can’t run it directly. Once net metering is approved they earn credits by day that offset the night bill, and the batteries keep the room cool through a night brownout. The smallest system we price is more than it needs.
Scenario B · work from home
Day 70%Night 30%
Two aircons run in the sunniest hours, so most of their electricity comes straight from the roof. Panels sized for daytime use leave the bedroom on the grid, or on the batteries in a brownout.
Scenario C · family home
Day 46%Night 54%
Most of this home’s aircon use is after dark, so offsetting it takes several times the panels that daytime use alone needs. That only pays if net metering is approved and your feeder can take the exports.
Prices are installed list prices from our itemised quote (±8%), never below 4 panels, before any promotion. Savings value self-used solar at the full rate and exports at 55% of it, and count only the aircons. Ready-made configurations are in our solar packages.
The same equipment as every system we quote, sized around when your aircons run. Warranty terms are confirmed in your proposal.
Monthly aircon cost at current rates
Night use at the middle of each planning range, 8 hours a day for 30 days. Rates are each utility’s latest published figure (CEBECO II from the ICSC PRESYO tracker).
| Utility and rate | 1 HP inverter | 1.5 HP inverter | 2 HP inverter | 1 HP window |
|---|---|---|---|---|
| MECO₱15.98/kWh · Sep 2026 | ₱1,918 | ₱2,493 | ₱3,931 | ₱3,068 |
| VECO₱14.89/kWh · Sep 2026 | ₱1,787 | ₱2,323 | ₱3,663 | ₱2,859 |
| CEBECO I₱15.24/kWh · Sep 2026 | ₱1,829 | ₱2,377 | ₱3,749 | ₱2,926 |
| CEBECO IIabout ₱15.9/kWh · Sep 2026, ICSC tracker | ₱1,909 | ₱2,482 | ₱3,914 | ₱3,055 |
| CEBECO III₱15.08/kWh · Oct 2026 | ₱1,810 | ₱2,352 | ₱3,710 | ₱2,895 |
Cebu household rates rose about 19–45% in the year to September 2026, and they move by ₱0.50–₱1.00/kWh in a typical month, up or down. In April and May the same aircon also works harder in the heat, so a 1 HP unit that costs about ₱1,787 a month to run at night today can cost a different amount even when your habits don’t.
Your utility also sets what your exports earn. Our local guides cover rates, net metering and brownouts for each:
How exports are credited, utility by utility: net metering in Cebu. More guides in the solar guides hub, or see how solar works, step by step.
STRAIGHT ANSWERS
The questions Cebu homeowners ask most when their aircons are the reason for going solar.
About 2 panels of 620 W for a 1 HP inverter split that runs 8 hours while the sun is up. It uses roughly 4.0–4.8 kWh in those hours, and each kWp of panels makes about 3.7 kWh on an average Cebu day, so it needs 1.1–1.3 kWp. A 1.5 HP inverter unit needs 2–3 panels, a 2 HP unit about 4 and a 1 HP window type about 3.
Those panels only cover daytime running. The same aircon at night needs a battery charged by extra panels (about 1.2 kWp more), or about 1.8 times the panels if you offset it through net-metering credits. These are planning estimates; the estimator on this page works it out for your own units and hours.
About 4 panels of 620 W for a 2 HP inverter split that runs 8 hours while the sun is up. It uses roughly 8.2–9.6 kWh in those hours, so it needs 2.2–2.6 kWp of panels. Running it 8 hours a day costs about ₱3,663–₱4,288 a month at ₱14.89/kWh (VECO, Sep 2026).
At night a 2 HP inverter unit averages about 1.0 kWh an hour, so on a battery with essentials it runs about 2.4 hours per battery. Its 1,715 W rated input plus essentials also comes close to the 2.6 kW a typical 50 A battery module supplies, so plan on at least two batteries if it must stay on in a brownout. These are planning estimates; the estimator on this page works it out for your own hours.
It depends on when your aircon runs, but here is what our itemised prices give today. Our itemised pricing starts at 4 panels (2.48 kWp) with a Deye 5 kW hybrid inverter, mounting, installation, permits and net-metering paperwork: ₱110,000–₱129,000 at list price. It makes about 9.2 kWh on an average day, close to the 8.0–9.6 kWh two 1 HP inverter aircons use in 8 daytime hours. A typical inverter refrigerator adds about 1.4 kWh a day (the 60 W average in our calculator’s appliance list; check your own label), and it is already part of the essentials in the battery figures on this page.
To keep a bedroom aircon on through a night brownout, add two 5.12 kWh batteries at ₱52,000 each: about ₱206,000–₱242,000 in total. Every price is itemised, and the final figure is confirmed in your written proposal after a site assessment.
Not directly: panels stop producing at sunset. There are two ways to cover night use. A battery stores daytime solar and runs the aircon after dark. Each 5.12 kWh battery delivers about 3.69 kWh, so a 1 HP inverter unit plus essentials runs about 3½–4½ hours per battery, and we recommend two whenever an aircon is on backup. To cut the night bill rather than just ride out brownouts, extra panels have to charge the battery by day.
The other way is net metering. Daytime surplus is exported and credited at your utility’s generation charge, about 55–65% of the household rate in late 2026. Credits lower the night bill, but they don’t keep the aircon on in a brownout.
First check what “5 kW” means: panels are rated in kWp, the inverter in kW, and the two often differ. Eight 620 W panels make 4.96 kWp, about 18 kWh on an average Cebu day. That covers the daytime running of two 1.5 HP inverter aircons for 8 hours (about 13 kWh at the top of the planning range), with some left for the rest of the house.
A 5 kW Deye hybrid inverter can supply up to 5 kW during a brownout when the panels and batteries can deliver it, more than the rated input of three 1.5 HP inverter units (3.1 kW). After dark the batteries set the limit: a typical 50 A battery module supplies about 2.6 kW, so backup power depends on the battery modules as well as the inverter. Your battery model’s rating is confirmed in your proposal.
No. The panels and installation cost money up front, and only daytime use is covered directly. What solar does is replace grid electricity you would otherwise buy at ₱14.89/kWh (VECO, Sep 2026). In the estimator’s starting example (a 1 HP bedroom unit at night and a 1.5 HP unit mostly by day), 2 panels sized for the daytime use save about ₱1,805 of a ₱4,512 monthly aircon cost. Our itemised pricing starts at 4 panels, which would save about ₱3,189 on the aircons and also cover other daytime loads. The rest of the night use is still paid for, or offset by credits at a lower value.
Savings depend on your hours, the weather and future rates, so treat every figure on this page as an estimate, not a promise.
Search results for “solar aircon” are mostly AC/DC “hybrid” aircon units, many of them online marketplace listings. They are a different product, and we don’t sell or assess them, so we can’t compare their performance here. A rooftop system works with the aircons you already own, powers the rest of the house too, and, once net metering is approved, earns credits for any surplus.
If you’re buying a new aircon anyway, compare the CSPF on the DOE energy label: higher is better.
No. Solar runs both types. But on a Cebu night a 1 HP window unit uses roughly 0.7–0.9 kWh an hour against 0.4–0.6 for a 1 HP inverter split, so it needs more panels for daytime use and drains a battery faster at night: about 2.8 hours per battery with essentials, against 3.7 for the inverter unit. If a window unit is near the end of its life anyway, replacing it with an inverter split before you size a battery can keep the battery count down. We size for the aircons you actually have.
THREE WAYS TO MOVE FORWARD
Run your own numbers, ask for a site assessment and an itemised quote, or put a question to a person first. Your aircon choices from the estimator travel with any request.
Your system, installed price and savings in about 30 seconds. No contact details needed.
Start the calculatorRoute BShare a few details and we’ll prepare a proposal after a site assessment.
Request my quoteRoute CHave a question first? Ask it here and get a straight answer.
Ask a questionROUTE A · INSTANT ESTIMATE
The same calculator and prices as the rest of the site. Your estimate stays on your screen unless you ask us to contact you.
Your promo code takes 10% off your system estimate, up to ₱50,000.
Choose your usual monthly bill. An estimate is all you need.
Using VECO at ₱14.89/kWh · Sep 2026. You can change your provider later.
About 30 seconds · No obligation
ROUTES B & C · TALK TO US
Every quotation follows a site assessment of your roof, wiring and priorities, so the price you approve is the price of the system you get.
Tell us about your aircons and roof. We’ll confirm the sizing at a site assessment and send an itemised proposal.
Not ready for a quote? Ask about running your aircons on solar and we’ll reply by phone or email.
Reviewed 16 October 2026 · Aircon figures are planning estimates; our prices are calculated live from our itemised component list
Label kWh = rated kW × 9 h × 30 × 0.5 (inverter) or 0.8 (fixed-speed); CSPF basis; 2021 minimums. Accessed 16 Oct 2026.
Draft star bands. Whether they are in force is unconfirmed, so this page doesn’t quote star cut-offs. Accessed 16 Oct 2026.
2.70 kW cooling, 770 W rated input, EER 3.50. Accessed 16 Oct 2026.
3.52 kW cooling, 1,030 W rated input. Accessed 16 Oct 2026.
1,715 W rated input, CSPF 5.25. Accessed 16 Oct 2026.
Power input 315 ~ 1,850 ~ 2,600 W (min ~ rated ~ max), 6.30 kW rated cooling, EER 3.41. The 2.5 HP planning range on this page is scaled from the 2 HP unit, so it is an estimate. Accessed 17 Oct 2026.
1 HP: 880 W, CSPF 3.37; 1.5 HP: about 1,120 W. Listing extract: read from search-result summaries because the pages block fetching, so these window figures are treated as estimates. 16 Oct 2026.
Manufacturer table of monthly kWh at 8 h a day; 25 °C recommendation. Published 6 Aug 2026, accessed 16 Oct 2026.
ISO 16358 defaults: at 29 °C vs 35 °C outdoors, +7.7% capacity and −8.6% power input; EER rated at 35 °C outdoors / 27 °C indoors; part-load example (1,080 W full vs 432 W half). May 2021.
Survey of 386 consumers, mostly middle- and high-income: 61% run their aircon more than 6 h a day. Jan 2023.
₱14.89/kWh for a 200 kWh home. Posted 26 Sep, updated 28 Sep 2026.
₱15.9806/kWh after VAT; generation charge ₱9.7611. Posted 1 Oct 2026.
₱15.24/kWh at 100 kWh. Accessed 16 Oct 2026.
About ₱15.08/kWh at 100 kWh including the meter fee. Posted 9 Oct 2026. CEBECO II (about ₱15.9, Sep 2026) is from the ICSC PRESYO tracker: presyo.icsc.ngo.
Exports are credited at the utility’s generation charge, not the retail rate. Issued 27 Aug 2025.
About 1,367–1,420 kWh per kWp a year; this page uses a cautious 1,350. Run 16 Oct 2026.
Mean air temperature 27.1 °C; about 28.1–28.7 °C in April–May. Accessed 16 Oct 2026.
Off-grid peak power: 2× rated for 10 s. File dated 11 Sep 2026.
Air conditioners need at least 2–3 minutes to restart after power returns. File dated 27 Apr 2026.
80% recommended depth of discharge; 50 A maximum per module (about 2.6 kW at 51.2 V). The battery model behind our price is confirmed in your proposal. 18 Mar 2026.
93 yellow and 30 red alerts, 1 Jan–3 Sep 2026 (NGCP). 3 Sep 2026.
SunStar reports shortages likely through 2027; Energy Secretary Garin: “it will be a 2028”. 12 Oct 2026.
Example red-alert window, 3–8 p.m. on 11 Aug 2026. 12 Aug 2026.
Your aircons, your numbers
Enter your units and hours, see the kWh, panels, batteries and price, then get a whole-home estimate from your own bill. No sign-up.
YOUR NEXT QUESTION
Each guide answers one question properly, with the numbers and sources behind it.